Revised August 27 2013 DOP PAO HEPA IntegrityTesting Procedure
DOP DOP or Dioctyl Phthalate is a liquid chemical which produces mono or poly -dispersed test aerosol of sub-micron particles, generated to challenge (evaluate integrity) of HEPA filters. Designated Substance Hazardous Materials (asbestos, lead, silica, mercury and others) designated
DOP Testing Procedure - Air Techniques International
training in the use of the testing equipment and the required procedures for field testing noted in this guideline. In-house training should be provided by a competent person as defined by the OH&S Act. 8) Service providers should have adequate insurance for conducting DOP/PAO Testing Procedure and should be updated on a regular basis as required.
DOP Testing Procedure - EACO / dop-testing-procedure-eaco.pdf
DOP Testing Procedure - EACO EACO DOP / PAO TestingGUIDELINE 2013 Foreword The guideline promotes industry standards for training, equipment, and methodologies for HEPA filter integrity Testingof negative air units, vacuums and any other HEPA filtered equipment on abatement and remediation projects.
DOP Testing Procedure - EACO - Environmental / dop-testing
DOP Testing Procedure - EACO - Environmental EACO DOP / PAO Testing GUIDELINE 2013 Foreword The guideline promotes industry standards for training, equipment, and methodologies for HEPA filter integrity Testing of negative air units, vacuums and any other HEPA filtered equipment on abatement and remediation projects.
DOP/PAO Testing of HEPA Filtered Equipment - Hazmasters
DOP/PAO HEPA testing is key to creating safer work environments and ensuring HEPA filtration equipment is compliant with regulations and manufacturers' specifications. DOP/PAO testing is available both on-site and within our facilities.
- What is a DOP test?
- DOP testing is a very quick process that tests the integrity of the HEPA (High Efficiency Particulate Air) filter using Dioctyl Phthalate (DOP liquid) in it's operational condition.
- What is the procedure for DOP testing of HEPA filter?
- To lay down the procedure for DOP testing (Integrity Testing) of HEPA filter. This SOP shall be is applicable for HVAC system, Laminar Air Flow stations and air handlers of process equipment. 5.1 DOP test of HEPA filters to be performed by an outside agency and the head engineering should ensure that this SOP is followed by outside agency.
- How often should a DOP test be performed?
- 5.17 The DOP test for the HEPA filters of HVAC system and process equipment shall be performed once in a year and HEPA filters of the LAF shall be performed once in a six months. 5.18 The DOP testing shall be carried out as per DOP testing schedule.