GC/MS Method for the Determination of Adipate Plasticizers
A GC/MS method was developed and successfully validated for the determination of adipate plasticizers in ham sausage migrated from polyvinylidene chloride (PVDC) packaging film. The sample...
GC/MS Method for the Determination of Adipate Plasticizers
ABSTRACT: A GC/MS method was developed and successfully validated for the determination of adipate plasticizers in ham sausage migrated from polyvinylidene chloride (PVDC) packaging film. The sample pretreatment includes liquid extraction, solvent evaporation, and reconstitution before and after solid phase extraction (SPE).
GC/MS Method for the Determination of Adipate Plasticizers
GC/MS Method for the Determination of Adipate Plasticizers in Ham Sausage and Its Application to Kinetic and Penetration Studies D.Y. WEI,M.L.WANG,Z.Y.GUO,S.WANG,H.L.LI,H.N.ZHANG,AND P.P. G AI ABSTRACT: A GC/MS method was developed and successfully validated for the determination of adipate plasti-
Development and Validation of Gas Chromatography-Triple
A method for the quantitative determination of dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), bis(2-ethylhexyl) adipate (DEHA), bis(2-ethylhexyl) phthalate (DEHP), di-n-octyl phthalate (DNOP), dioctyl terephthalate (DOTP), diisononyl phthalate (DINP), and diisodecyl phthalate (DIDP) in medical infusion sets was developed and validated
GC Method for Determining Polyadipate Plasticizers in Foods
A GC/MS method was developed for simultaneous determination of 12 phthalates and four other plasticizers--acetyl tributyl citrate, di(2-ethylhexyl) adipate, dibutyl sebacate, di-isononyl
- Can GC-MS be used to analyze phthalates and assimilated analytes?
- Analysis using GC-MS with a single quadrupole mass analyzer has been typically used in most cases for the determination of phthalates and assimilated analytes in medical devices. However, this method requires a clean matrix to avoid the interference of unwanted ions .
- Can polymer dissolution method be used to determine regulated plasticizers?
- 4. Conclusion The suitability of solvent extraction with the polymer dissolution method followed by the GC-MS/MS MRM mode for the determination of eight regulated plasticizers (DBP, BBP, DEHA, DEHP, DNOP, DOTP, DINP, and DIDP) in the tubing of medical infusion sets was described.
- Which solvent extraction method was used before GC-MS/MS analysis?
- Solvent extraction with polymer dissolution for sample preparation was employed prior to GC-MS/MS analysis. Average recoveries of the eight target analytes are typically in the range of 91.8–122% with the relative standard deviations of 1.8–17.8%.
- Why do we need to identify toxic plasticizers in medical devices?
- Accordingly, the identification and quantification of toxic plasticizers in medical devices, especially the tubings of medical infusion sets, are needed since they are able to leach from infusion sets and result in human exposure directly.