Standard Test Method for Purity of Monomeric Plasticizers by
Scope1.1 This gas chromatographic test method covers a procedure for extending the range of purity determination of monomeric plasticizers beyond that now determined by other methods. Due to the need to volatilize the plasticizer, only monomeric plasticiz Standard Test Method for Purity of Monomeric Plasticizers by Gas Chromatography
Standard Guide for Purity of Monomeric Plasticizers by Gas
ASTM D3465-21 Standard Guide for Purity of Monomeric Plasticizers by Gas Chromatography Significance and Use 5.1 Infrared techniques frequently cannot detect low-level materials. Gas chromatographic methods possess higher sensitivity and are used to extend limits of detection.
D3465 - Standard Guide for Purity of Monomeric Plasticizers
Standard Test Method for Purity of Monomeric Plasticizers by Gas Chromatography This gas chromatographic test method covers a procedure for extending the range of purity determination of monomeric plasticizers beyond that now determined by other methods. Due to the need to... ASTM D3465 December 26, 1975
ASTM International - ASTM D3465-00 - Standard Test Method
Standard Test Method for Purity of Monomeric Plasticizers by Gas Chromatography 1.1 This gas chromatographic test method covers a procedure for extending the range of purity determination of monomeric plasticizers beyond that now determined by other methods. Due to the need to... ASTM D3465-00 August 10, 2000
ASTM D 3465 : 2014 Standard Test Method for Purity of Monomeric
Buy ASTM D 3465 : 2014 Standard Test Method for Purity of Monomeric Plasticizers by Gas Chromatography from SAI Global
- What impurities can be found in monomeric plasticizers?
- 5.3 Impurities potentially found in monomeric plasticizers include alcohols, dibasic acids, and monoesters. 1.1 This gas chromatographic guide covers a procedure for extending the range of purity determination of monomeric plasticizers beyond that now determined by other methods.
- What is standard guide for purity of monomeric plasticizers by gas chromatography?
- Standard Guide for Purity of Monomeric Plasticizers by Gas Chromatography1This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued b
- Which plasticizers can be volatilized?
- Due to the need to volatilize the plasticizer, only monomeric plasticizers having definitive boiling points and a molecular weight less than 1000 Daltons, such as dioctyl phthalate, are applicable to this guide. 1.2 The values in SI units are to be regarded as standard.
- What if area percent of plasticizer is less than 99 %?
- However, if the area percent of the plasticizer is less than 99.0 % or if any question were to arise about the data, an internal standard shall be used. 5.3 Impurities potentially found in monomeric plasticizers include alcohols, dibasic acids, and monoesters.
- Where can I find referenced ASTM standards?
- t previous edition approved in 2014 as D3465 - 14. DOI: 10.1520/D3465-21.2 For referenced ASTM standards, visit the ASTM w bsite, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume inform se of the Inte